Related Experiment Video
Updated: Aug 30, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
GLP-1 receptor agonist use during hospitalisation: Better glycaemic control compared to premixed insulin
Morgan Jervis1, Antonine Pineau Mitchell2, Nafseen Islam1
1Faculty of Life Sciences & Medicine, King's College London, London, UK.
Introduction:
Glycaemic control associates with better outcomes for hospitalised patients. Whether GLP-1 receptor agonists (GLP-1 RA) are suitable and effective drugs for inpatients is unclear.
Methods:
A retrospective, single centre, observational study using data from the electronic health record. Patients admitted using GLP-1 RA as outpatients, from 2016 to 2019, were identified. Outcomes were compared to those admitted using twice-daily (BD) mixed insulin. Capillary glucose, medication use, creatinine, and demographic data were collected. As drugs may be discontinued/not administered in hospital, days when GLP-1 RA was administered were 'GLP-1 RA active' and, for insulin, 'insulin active'. The primary comparison was rate of hypoglycaemia (<4 mmol/L) and severe hypoglycaemia (<3 mmol/L). A logistic regression model examined variables for hypoglycaemia.
Results:
GLP-1 RA comprised n = 262 admissions and BD insulin n = 166. The 'insulin active' cohort (n = 957 patient days) had higher risk of hypoglycaemia than 'GLP-1 RA active' (n = 806 days); occurring on 14.7% of days; 95% confidence interval [CI] 12.6-17.1 versus 9.9% days; 95% CI 8.0-12.2; p = 0.002, and severe hypoglycaemia 4.0% of days (95% CI 2.8-5.4) versus 2.0% (95% CI 1.1%-3.2%; p = 0.005). Daily glucose (mean ± standard deviation) was 10.8 ± 5.2 mmol/L in insulin active versus 9.6 ± 4.7 mmol/L in GLP-1 RA active; p < 0.001. Insulin use, age, and acute admissions predicted hypoglycaemia. The odds ratio for hypoglycaemia was 2.15 times greater (95% CI, 1.14-4.08; p = 0.019) with insulin than with GLP-1 RA.
Conclusions:
GLP-1 RA provided better glycaemic control than BD mixed insulin and should be continued during hospitalisation unless there is a clear indication for cessation.
Related Concept Videos
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Oral Hypoglycemic Agents: Glinides
Dipeptidyl Peptidase 4 Inhibitors
Hypoglycemia and Glucagon
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...

