Maximal oxygen uptake ( ) is the criterion measure of cardiorespiratory fitness. Lower cardiorespiratory fitness is a strong predictor of poor health outcomes, including all-cause mortality. Because testing is resource intensive, several non-exercise-based V˙O 2max prediction equations have been published. We assess these equations' ability to predict measured V˙O 2max , recalibrate these equations, and quantify the association of measured and predicted V˙O 2max with all-cause mortality.
Methods:
Baltimore Longitudinal Study of Aging participants with valid V˙O 2max tests were included ( n = 1080). Using published V˙O 2max prediction equations, we calculated predicted V˙O 2max and present performance metrics before and after recalibration (deriving new regression estimates by regressing measured V˙O 2max on Baltimore Longitudinal Study of Aging covariates). Cox proportional hazards models were fit to quantify associations of measured, predicted, and recalibration-predicted values of V˙O 2max with mortality.
Results:
Mean age and V˙O 2max were 69.0 ± 10.4 yr and 21.6 ± 5.9 mL·kg -1 ·min -1 , respectively. The prediction equations yielded root mean square error values ranging from 4.2 to 20.4 mL·kg -1 ·min -1 . After recalibration, these values decreased to 3.9-4.2 mL·kg -1 ·min -1 . Adjusting for all covariates, all-cause mortality risk was 66% lower for the highest quartile of measured V˙O 2max relative to the lowest. Predicted V˙O 2max variables yielded similar estimates in unadjusted models but were not robust to adjustment.
Conclusions:
Measured V˙O 2max is an extremely strong predictor of all-cause mortality. Several published V˙O 2max prediction equations yielded the following: 1) reasonable performance metrics relative to measured V˙O 2max especially when recalibrated, and 2) all-cause mortality hazard ratios similar to those of measured V˙O 2max , especially when recalibrated, yet 3) were not robust to adjustment for basic demographic covariates likely because these were used in the equation for predicted V˙O 2max .
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...