A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study
Related Experiment Video
Updated: Aug 29, 2025

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
1Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Abstract:
Unlike traditional pulse transit time (PTT), continuous PTT (CPTT) can be used to calculate PTT from all samples within the cardiac cycle. It has the potential to be utilized for continuous blood pressure (BP) estimation. This study evaluated the feasibility of CPTT as a non-invasive consecutive blood pressure estimation method in 20 volunteers. The CPTT was calculated with a time delay in all discrete samples of photoplethysmograms measured at two different body sites. BP was then calculated with a regression equation. For comparative evaluation, BP based on PTT was also estimated. Continuous blood pressure was measured using a non-invasive volume clamp BP monitoring device. Four types of BP measurement, systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and pulse pressure (PP), were estimated using PTT and CPTT. Correlation coefficients and root-mean-squared-error (RMSE) were used for evaluating BP estimation performance. For estimating SBP, DBP, PP, and MAP, PTT-based BP estimation showed correlations of .407, .373, .410, and .286, respectively, and CPTT-based BP estimation showed correlations of .436, .446, .506, and .097, respectively. With PTT-based estimation, the RMSE between the estimated BP and the baseline BP was 5.44 ± 1.56 mmHg for SBP, 3.14 ± 0.46 mmHg for DBP, 3.66 ± 0.70 mmHg for MAP, and 3.73 ± 1.31 mmHg for PP. The estimated BP using CPTT showed RMSE of 5.36 ± 1.39 mmHg for SBP, 3.02 ± 0.49 mmHg for SBP, 3.44 ± 0.63 mmHg for MAP, and 3.91 ± 1.41 mmHg for PP.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure