Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Coherence Function and Adaptive Noise Cancellation Performance of an Acoustic Sensor System for Use in Detecting
Matthew Fynn1, Sven Nordholm1, Yue Rong1
1School of Electrical Engineering, Computing and Mathematical Sciences (EECMS), Faculty of Science and Engineering, Curtin University, Bentley, WA 6102, Australia.
Abstract:
Adaptive noise cancellation is a useful linear technique to attenuate unwanted background noise that cannot be removed using traditional frequency-selective filters. Usually, this is due to the signal and noise co-existing in the same frequency band. This paper tests a weighted least mean squares (WLMS) algorithm on a stethoscope system for use in detecting coronary artery disease in the presence of background noise. Each stethoscope is equipped with two microphones: one used to detect heart signals and one used to detect background noise. The WLMS method was used for four different sources of background noise whilst measuring a heartbeat, including a single tone, multiple tones, hospital/clinic noise, and breathing noise. The magnitude-squared coherence between both microphones was unity for the tone scenarios, resulting in complete attenuation. For the other background noise sources, a less-than-unity magnitude-squared coherence resulted in minor and no attenuation. Thus, the coherence function is a tool that can be used to predict the amount of attenuation achievable by linear adaptive noise-cancellation techniques, such as WLMS, as presented in this article.
More Related Videos
05:58Testing Acetylcholine Followed by Adenosine for Invasive Diagnosis of Coronary Vasomotor Disorders
Published on: February 3, 2021
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease I: Introduction
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...