Related Experiment Video
Updated: Aug 29, 2025

Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging to Study Detailed Bone Apposition
Gina M Mosich1, Hollis G Potter2, Matthew F Koff2
1Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA.
Background:
The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation may allow a better understanding of implant design and longevity. A new cementless total knee arthroplasty (TKA) was introduced, and we hypothesized that this cementless system would show similar fixation compared to a cemented system as assessed by multispectral MRI.
Methods:
Multiacquisition variable-resonance image combination selective MRI was performed in 20 patients implanted with a cementless TKA. A matched control group of 20 patients who had a cemented TKA was also evaluated. Each patellar, femoral, and tibial component was graded globally as well as by specific zones. The patella zones were medial, lateral, superior, and inferior. The femoral and tibial components were divided into 4 zones: anteromedial, anterolateral, posteromedial, and posterolateral. Integration grades were performed for each zone as follows: (1) normal, (2) fibrous tissue, (3) fluid interface, (4) osteolysis. A Chi-square test was performed to detect differences in level of integration grades between patients with cemented and those with cementless TKA.
Results:
At average 16-month follow-up, the cementless group grading noted 0/80 (0%) vs 2/76 (2.63%) patellar zones with fluid interface, 0/80 (0%) vs 26/80 (32.5%) femoral zones with fibrous tissue, and 10/80 (12.5%) vs 17/80 (21.25%) tibial zones with fibrous tissue. The analysis showed patellar (P < .001), femoral (P < .001), and tibial (P < .001) components had improved fixation and less percentage of fibrous tissue and fluid present in the cementless TKA.
Conclusions:
Utilizing metal suppression MRI, a newer cementless knee implant demonstrated excellent biologic fixation and improved fixation compared to the cemented group.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging