Related Experiment Video
Updated: Aug 8, 2026

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
Microplastics' analysis in water: Easy handling of samples by a new Thermal Extraction Desorption-Gas
Débora Sorolla-Rosario1, Julio Llorca-Porcel1, Mónica Pérez-Martínez2
1Labaqua, S.A. C/ Dracma 16-18 Pol., Industrial Las Atalayas, 03114, Alicante, Spain.
Abstract:
Thermal Extraction-Desorption (TED) using a thermobalance coupled to a gas chromatograph (GC) with mass spectrometer (MS) detector is an extended method for polymers identification in complex matrixes. A new TED-GC/MS method for microplastics identification is developed in this study, where the whole filter with solids collected from water is thermal treated in a furnace, instead of using a small portion in a Thermogravimetric analysis (TGA) device, avoiding sample handling. Pyrolyzing the whole filter in a tubular furnace has advantages with respect to the standard procedure of using a TGA with a small crucible in TED-GC/MS. The main advantage is the easy manipulation of the sample, since the filter does not have to be manipulated to extract the sample or cut some portions, avoiding sample losses during handling and ensuring that inhomogeneity on the filter surface is not a problem. Furthermore, there are no limitations on the weight of the sample beyond the adsorbent's ability to trap decomposition compounds without becoming saturated, so high intensity signals can be obtained in order to avoid confuse signals with noise, false negatives or values so close of the quantification limit.
More Related Videos
05:31Sampling, Sorting, and Characterizing Microplastics in Aquatic Environments with High Suspended Sediment Loads and Large Floating Debris
Published on: July 28, 2018
09:10Multimodal Analysis of Microplastics in Drinking Water using a Silicon Nanomembrane Analysis Pipeline
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...