Conduction system pacing versus conventional pacing in patients undergoing atrioventricular node ablation:
Pugazhendhi Vijayaraman1, Andrew J Mathew1, Angela Naperkowski1
1Geisinger Heart Institute, Wilkes Barre, Pennsylvania.
Background:
Atrioventricular node ablation (AVNA) with right ventricular or biventricular pacing (conventional pacing; CP) is an effective therapy for patients with refractory atrial fibrillation (AF). Conduction system pacing (CSP) using His bundle pacing or left bundle branch area pacing preserves ventricular synchrony.
Objective:
The aim of our study is to compare the clinical outcomes between CP and CSP in patients undergoing AVNA.
Methods:
Patients undergoing AVNA at Geisinger Health System between January 2015 and October 2020 were included in this retrospective observational study. CP or CSP was performed at the operators' discretion. Procedural, pacing parameters, and echocardiographic data were assessed. Primary outcome was the combined endpoint of time to death or heart failure hospitalization (HFH) and was analyzed using Cox proportional hazards. Secondary outcomes were individual outcomes of time to death and HFH.
Results:
AVNA was performed in 223 patients (CSP, 110; CP, 113). Age was 75 ± 10 years, male 52%, hypertension 67%, diabetes 25%, coronary disease 40%, and left ventricular ejection fraction (LVEF) 43% ± 15%. QRS duration increased from 103 ± 30 ms to 124 ± 20 ms (P < .01) in CSP and 119 ± 32 ms to 162 ± 24 ms in CP (P < .001). During a mean follow-up of 27 ± 19 months, LVEF significantly increased from 46.5% ± 14.2% to 51.9% ± 11.2% (P = .02) in CSP and 36.4% ± 16.1% to 39.5% ± 16% (P = .04) in CP. The primary combined endpoint of time to death or HFH was significantly reduced in CSP compared to CP (48% vs 62%; hazard ratio 0.61, 95% confidence interval 0.42-0.89, P < .01). There was no reduction in the individual secondary outcomes of time to death and HFH in the CSP group compared to CP.
Conclusion:
CSP is a safe and effective option for pacing in patients with AF undergoing AVNA in high-volume centers.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
