Spectral denoising based on Hilbert-Huang transform combined with F-test

Xihui Bian1,2,3, Mengxuan Ling1,2,3, Yuanyuan Chu1

  • 1Key Laboratory of Separation Membranes and Membrane Processes, School of Chemical Engineering and Technology, Tiangong University, Tianjin, China.

Frontiers in Chemistry
|September 16, 2022
PubMed

Related Concept Videos

Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
1.8K
Expected Frequencies in Goodness-of-Fit Tests01:19

Expected Frequencies in Goodness-of-Fit Tests

A goodness-of-fit test is conducted to determine whether the observed frequency values are statistically similar to the frequencies expected for the dataset. Suppose the expected frequencies for a dataset are equal such as when predicting the frequency of any number appearing when casting a die. In that case, the expected frequency is the ratio of the total number of observations (n)  to the number of categories (k).
2.6K
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.2K
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
862
Behrens–Fisher Test00:57

Behrens–Fisher Test

The Behrens-Fisher test is a statistical method designed to address the Behrens-Fisher problem, which arises when comparing the means of two normally distributed populations with unequal variances. Unlike the Student's t-test, which assumes equal variances, the Behrens-Fisher test allows for mean comparison without this restrictive assumption. This flexibility makes it particularly valuable in scenarios where two independent samples exhibit normality but lack variance homogeneity.
This test...
124
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.1K