Related Experiment Video
Updated: Aug 28, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Quantitative Evaluation of Apically Extruded Debris during Biomechanical Preparation using Hand K-File, Protaper
Diksha Maheswari1, Rashmi Rekha Mallick2, Ashutosh Shandilya1
1Department of Conservative Dentistry and Endodontics, Government Dental College, Raipur, Chhattisgarh, India.
Background:
The instrumentation technique which produces least amount of apically extruded debris is desirable to use in biomechanical preparation of root canal.
Aim:
To quantitatively evaluate apically extruded debris during instrumentation with hand K-file, ProTaper Next, and WaveOne.
Materials And Methods:
Forty-five extracted human single-rooted mandibular premolars with straight, single canal and single apical foramen were selected after radiographic evaluation and divided equally into three groups. Cleaning and shaping was done using hand K-files in step-back technique, ProTaper Next, and WaveOne single-file system. Debris extruded apically was collected into Eppendorf tubes and stored in an incubator at 37°C temperature for 5 days for drying. Weight of dry debris was measured using electronic microbalance with an accuracy of 10-5 g.
Statistical Analysis:
Student's t-test, with P value < 0.05 is statistically significant.
Results:
Statistically significant (P < 0.05) amount of debris was extruded by all three instrumentation systems: hand K-file- 1.9220 mg, ProTaper Next- 1.4940 mg, and WaveOne- 0.9940 mg. Least amount of debris produced by WaveOne was statistically significant (P < 0.05) when compared with the other two systems.
Conclusion:
The WaveOne reciprocating system extruded least amount of debris in comparison to hand K-file and ProTaper Next.