Related Experiment Video
Updated: Aug 28, 2025

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Bayesian inference of spectrometric data and validation with numerical simulations of plasma sheath diagnostics of a
Gonzalo Avaria1,2, Alejandro Clausse3, Sergio Davis4,5
1Research Center on the Intersection in Plasma Physics, Matter and Complexity, P2mc, Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago, Chile. gonzalo.avaria@cchen.cl.
Abstract:
Plasma Foci are pulsed coaxial discharges with numerous radiation applications and interesting scientific phenomena. Although the physics answered much of the processes involved in these discharges, many related fundamental questions still remains doggedly unresolved. One of the obstacles to deeper knowledge is the scarcity of reliable experimental data. This work presents an elaborate experimental assessment of the electron density in the rundown phase of a 400 J Plasma Focus operating with hydrogen. The rundown of the plasma sheath is basically a hypersonic shock wave between two coaxial electrodes accelerated by the Lorentz force, and it is important to control the pinch formation. The electron density of the passing sheath is measured by means of the Stark broadened hydrogen alpha emission with spatial and temporal resolution. The experimental data is post-processed using Bayesian posterior probability assessment. The results are conflated with the numerical model CShock to construe an educated explanation of the sheath behavior during the rundown. In particular, it is possible to reckon the formation of a toroidal instability reported in previous experiments, and to estimate the plasma sheath temperature (4-20 eV) and velocity (62.5 km/s) at this stage.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

