Intrapatient variability of 18F-FDG uptake in normal tissues
Mohamed Hosny Mohamed Sayed1, Aya Km Abdelnaim1, Nsreen Ra Mohamadien1
1Department of Clinical Oncology and Nuclear Medicine, Faculty of Medicine, Assiut University, Assiut, Egypt.
Journal of Clinical Imaging Science
|September 21, 2022
Summary
The spleen and muscle demonstrated stable maximum standardized uptake value (SUVmax) in repeated 18F-FDG PET/CT scans, making them ideal reference tissues. Liver also showed stability but was influenced by more factors than spleen and muscle.
Area of Science:
- Nuclear Medicine
- Radiopharmacology
- Medical Imaging
Background:
- Standardized uptake value maximum (SUVmax) variability in normal tissues affects 18F-FDG PET/CT interpretation.
- Identifying stable reference tissues is crucial for accurate quantitative analysis.
Purpose of the Study:
- To assess the impact of serum glucose and other factors on SUVmax variability in normal tissues across repeated 18F-FDG PET/CT scans.
- To identify optimal reference tissues for quantitative imaging.
Main Methods:
- Retrospective analysis of 334 18F-FDG PET/CT scans from 167 patients, including 38 diabetics, with two scans per patient.
- SUVmax was calculated for ten normal tissues (brain, tonsil, blood pool, heart, lung, liver, spleen, bone marrow, fat, iliopsoas muscle).
- Correlations with serum glucose, BMI, injected dose, and uptake time were analyzed.
Main Results:
- Lung and heart SUVmax showed significant differences between scans (P=0.003, P=0.024).
- Brain SUVmax negatively correlated with glucose in diabetics (r=-0.537, P=0.001). Liver SUVmax correlated positively with BMI (r=0.416-0.453, P<0.001).
- Liver SUVmax was influenced by injected dose and uptake duration; spleen and muscle SUVmax were consistently affected only by injected dose.
Conclusions:
- Liver, muscle, and spleen exhibit satisfactory test-retest stability for use as reference tissues.
- Spleen and muscle are more optimal reference tissues due to their sole association with the injected 18F-FDG dose, minimizing confounding factors.