Related Experiment Video
Updated: Aug 28, 2025

Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022
Hardware-in-Loop Comparison of Physiological Closed-Loop Controllers for the Autonomous Management of Hypotension
Eric J Snider1, David Berard1, Saul J Vega1
1U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA.
Abstract:
Trauma and hemorrhage are leading causes of death and disability worldwide in both civilian and military contexts. The delivery of life-saving goal-directed fluid resuscitation can be difficult to provide in resource-constrained settings, such as in forward military positions or mass-casualty scenarios. Automated solutions for fluid resuscitation could bridge resource gaps in these austere settings. While multiple physiological closed-loop controllers for the management of hypotension have been proposed, to date there is no consensus on controller design. Here, we compare the performance of four controller types-decision table, single-input fuzzy logic, dual-input fuzzy logic, and proportional-integral-derivative using a previously developed hardware-in-loop test platform where a range of hemorrhage scenarios can be programmed. Controllers were compared using traditional controller performance metrics, but conclusions were difficult to draw due to inconsistencies across the metrics. Instead, we propose three aggregate metrics that reflect the target intensity, stability, and resource efficiency of a controller, with the goal of selecting controllers for further development. These aggregate metrics identify a dual-input, fuzzy-logic-based controller as the preferred combination of intensity, stability, and resource efficiency within this use case. Based on these results, the aggressively tuned dual-input fuzzy logic controller should be considered a priority for further development.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypertension and Regulation of Blood Pressure

