Hemodynamic Responses to Resistance Exercise with Blood Flow Restriction Using a Practical Method Versus a
Lee J Winchester1, Morgan T Blake1, Abby R Fleming1
1Exercise Physiology Laboratory, Department of Kinesiology, The University of Alabama, Tuscaloosa, AL 35487, USA.
Abstract:
The aim of this study was to examine the potential differences in acute hemodynamic responses and muscular performance outcomes following resistance exercise between traditional blood flow restriction (TRABFR) and a novel band tissue flossing method (BTFBFR).
Methods:
Fifteen healthy young adults (23.27 ± 2.69 years) visited the lab for three sessions (≥72 h apart). Each session's exercise consisted of three sets of 20 maximum-effort seated leg extensions and flexions with one of three conditions: control (CON), TRABFR (50% limb occlusion pressure (LOP)), or BTFBFR. During TRABFR and BTFBFR sessions, occlusion was applied immediately prior to exercise and removed immediately after. Heart rate was collected prior to exercise, after onset of occlusion, immediately after exercise, and one-minute after removal of occlusion. Ultrasonography was performed prior to, and at least 30 s after, occlusion.
Results:
BTFBFR caused greater reductions in arterial distance (14.28%, p = 0.010) and arterial area (28.43%, p = 0.020) than TRABFR. BTFBFR was able to significantly reduce arterial flow below pre-occlusion values, while TRABFR did not. Both conditions caused significant elevations in heart rate following occlusion (TRABFR: +4.67 bpm, p = 0.046 and BTFBFR: +6.07 bpm, p = 0.034), immediately post-exercise (TRABFR: +56.93 bpm, p < 0.001 and BTFBFR: +52.79 bpm, p < 0.001) and one-minute post-exercise (TRABFR: +15.71, p = 0.003 and BTFBFR: +14.57, p < 0.001). Only BTFBFR caused significant reductions in performance as measured by average power per repetition.
Conclusions:
BTFBFR causes a more exaggerated decrease in arterial blood flow as well as muscular power when compared to traditional TRABFR at 50% of LOP.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure