Criterion Validity of the Newly Developed Occlusal Cant Index
Hessah A Alhuwaish1, Khalid A Almoammar1, Abdulaziz S Fakhouri2
1Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia.
Objectives:
To assess the criterion-related (concurrent) validity of the newly developed occlusal cant index (OCI).
Materials And Methods:
Four standardized posterior-anterior (PA) cephalometric radiographs of four patients were obtained at a 0° occlusal cant (OC) and manipulated to create various degrees of OC from 1° to 4° on the right and left sides, with a total of 36 PA images. The angle between the actual horizontal line and the occlusal plane was manually drawn on each PA radiographic image. The set of radiographic images was displayed to 36 orthodontists, who were asked to measure the drawn angle and apply the OCI to each PA radiographic image.
Results:
The overall criterion-related validity of the OCI was statistically significant among all grades.
Conclusion:
The OCI is highly valid and recommended for clinical consideration.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
08:47Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or...