Related Experiment Video
Updated: Aug 28, 2025

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
3D RBSM Analysis of Bond Degradation in Corroded Reinforced Concrete as Observed Using Digital Image Correlation
1Institute of Industrial Science, The University of Tokyo, Tokyo 1538505, Japan.
Abstract:
The buildup of corrosion products over a reinforcing bar and associated reduction in rib height lead to degradation of the bond between reinforcement and concrete. The authors have previously used digital image correlation (DIC) to visualize and quantify load-induced cracking at the interface in specimens with varying degrees of corrosion. The results obtained in that study are used here to simulate the post-corrosion local bond behavior. A bond degradation model is incorporated into the discrete analysis tool, 3D Rigid Body Spring Model (RBSM) for the simulation. This analysis method allows the shape of the reinforcing bar to be directly modeled, and concrete cracking behavior is simulated by using a randomly shaped mesh. The magnitude of opening and sliding over the tips of ribs in the simulation, in which the reduction in rib height could not be modeled, is significantly lower than observed in the experiment. The results demonstrate that reduction in rib height is an important factor in post-corrosion behavior, and needs to be included in simulation models. It is also understood that in order to gain a better understanding of local post-corrosion bond behavior, de-bonding between reinforcement and concrete needs to be modeled in a discrete analysis framework.
Related Concept Videos
Non-destructive Tests for Concrete Strength
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Bonding and Strength of Aggregate
Microcracking in Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...

