A Novel Damping Control of Grid-Connected Converter Based on Optimal Split-Inductor Concept

Chao Chen1, Liwu Gong1, Wei Zhang1

  • 1Grid Pinghu Power Supply Company, Pinghu 314200, China.

Micromachines
|September 23, 2022
PubMed

Related Concept Videos

Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
305
Inductor in an AC Circuit01:16

Inductor in an AC Circuit

The basic components of an inductor are coils or loops of wire that are either wound around a hollow tube former or a ferromagnetic material (iron-cored) to increase their inductive value or inductance. When a voltage is applied across an inductor's terminals, a magnetic field is created, where the inductor stores its energy. The inductor's own self-induced or back emf value controls the growth of the current flowing through it.  This back emf voltage is proportional to the rate of...
2.5K
Energy Stored in Inductors01:16

Energy Stored in Inductors

An inductor is ingeniously crafted to accumulate energy within its magnetic field. This field is a direct result of the current that meanders through its coiled structure. When this current maintains a steady state, there is no detectable voltage across the inductor, prompting it to mimic the behavior of a short circuit when faced with direct current.
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
496
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
230
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
238
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
272