Related Experiment Video
Updated: Aug 27, 2025

Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
Published on: January 7, 2019
A PI Control Method with HGSO Parameter Regulator for Trajectory Planning of 9-DOF Redundant Manipulator
Meijiao Liu1,2, Tianyu Liu1,2, Mingchao Zhu1
1CAS Key Laboratory of On-Orbit Manufacturing and Integration for Space Optics System, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Abstract:
In order to solve the tracking accuracy problem of the redundant manipulator, a PI control method with Henry gas solubility optimization parameter regulator (PI-HGSO) is proposed in this paper. This method consists of the controller and the parameter regulator. The characteristic is that the position deviation of a manipulator is equivalent to a specific function; namely, the proportional-integral (PI) controller is used to adjust the deviation input. The error can be better corrected by the processing of the PI controller so that the inverse kinematics solution of the minimum error can be realized. At the same time, the parameter selection of PI controllers has always been a difficulty in controller design. To address the problem, Henry gas solubility optimization (HGSO) is selected as a parameter regulator to optimize the parameters and obtain the optimal controller, thereby achieving high-precision trajectory tracking. Experiments on 9-DOF redundant manipulator show that our method achieves competitive tracking accuracy in contrast with others. Meanwhile, the efficiency and accuracy of the PI controller are greatly guaranteed by using HGSO to automatically optimize controller parameters instead of making approximate adjustments through infinite manual trial and error. Therefore, the feasibility and competitive superiority of PI-HGSO is fully proved in trajectory planning of redundant manipulators.
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
PID Controller
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...