Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation
Vincent Fleischhauer1,2, Aarne Feldheiser3,4, Sebastian Zaunseder1,2
1Faculty of Information Technology, University of Applied Sciences and Arts Dortmund, 44139 Dortmund, Germany.
Abstract:
Blood pressure (BP) is among the most important vital signals. Estimation of absolute BP solely using photoplethysmography (PPG) has gained immense attention over the last years. Available works differ in terms of used features as well as classifiers and bear large differences in their results. This work aims to provide a machine learning method for absolute BP estimation, its interpretation using computational methods and its critical appraisal in face of the current literature. We used data from three different sources including 273 subjects and 259,986 single beats. We extracted multiple features from PPG signals and its derivatives. BP was estimated by xgboost regression. For interpretation we used Shapley additive values (SHAP). Absolute systolic BP estimation using a strict separation of subjects yielded a mean absolute error of 9.456mmHg and correlation of 0.730. The results markedly improve if data separation is changed (MAE: 6.366mmHg, r: 0.874). Interpretation by means of SHAP revealed four features from PPG, its derivation and its decomposition to be most relevant. The presented approach depicts a general way to interpret multivariate prediction algorithms and reveals certain features to be valuable for absolute BP estimation. Our work underlines the considerable impact of data selection and of training/testing separation, which must be considered in detail when algorithms are to be compared. In order to make our work traceable, we have made all methods available to the public.
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure