Related Experiment Video
Updated: Aug 27, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Seismocardiography as a tool for assessment of bi-ventricular pacing
Kasper Sørensen1, Peter Søgaard2, Kasper Emerek2
1Aalborg University, Department of Health Science and Technology, CardioTech, Denmark.
Abstract:
Objective.Conduction-induced heart failure in patients with left bundle branch block (LBBB) can benefit from cardiac resynchronization therapy (CRT). However, some patients are non-responders to the therapy with one contributing factor being poor optimization of the atrioventricular (AV) pacing delay. In this study, we have investigated the pacing-induced changes in the seismocardiogram (SCG).Approach.14 patients with heart failure, LBBB, and CRT were included. SCG was recorded with pacing turned on and off. Based on a mean SCG heartbeat from each patient, fiducial points were annotated, and cardiac timing intervals (CTI) and amplitudes were derived. These were compared between the CRT group and a group of healthy normal subjects (n= 14). Echocardiography was also used to derive CTI. Intervals derived from the SCG and echocardiogram were correlated.Main results.The isovolumetric contraction time (IVCT) derived from SCG was significantly shorter in the CRT group when the pacemaker was turned on (63.2-52.6 ms,p= 0.027). The first peak-to-peak amplitude in the systolic complex was significantly larger with the pacemaker turned on (p= 0.002), as well as the ∣max-min∣ amplitude in the systolic complex (p= 0.003). Isovolumetric relaxation time and left ventricular ejection time (LVET) were not significantly different between pacemaker settings. Compared to normal subjects, IVCT was significantly prolonged with the pacemaker turned off. All amplitudes were significantly larger in the healthy subject group. IVCT and LVET derived from SCG were significantly correlated to the echocardiogram.Significance.IVCT shortened and SCG amplitudes increased in response to CRT, indicating a more efficient ventricular contraction. This demonstrates the possibility to detect cardio-mechanic changes in response to treatment with the SCG. However, for the patients the systolic part of the SCG was abnormal and difficult to characterize, raising concerns about the correct interpretation of the SCG.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Mitral Stenosis II: Clinical features and Diagnostic Tests

