Evaluating the Utility of High Sensitivity Troponin in Blunt Cardiac Injury
Jay N Nathwani1, Matthew R Baucom1, Ann Salvator1
1Department of Surgery, University of Cincinnati, Cincinnati, Ohio.
Introduction:
Screening for blunt cardiac injury (BCI) includes obtaining a serum troponin level and an electrocardiogram for patients diagnosed with a sternal fracture. Our institution has transitioned to the use of a high sensitivity troponin I (hsTnI). The aim of this study was to determine whether hsTnI is comparable to troponin I (TnI) in identifying clinically significant BCI.
Materials And Methods:
Trauma patients presenting to a level I trauma center over a 24-mo period with the diagnosis of sternal fracture were screened for BCI. Any initial TnI more than 0.04 ng/mL or hsTnI more than 18 ng/L was considered positive for potential BCI. Clinically significant BCI was defined as a new-bundle branch block, ST wave change, echocardiogram change, or need for cardiac catheterization.
Results:
Two hundred sixty five patients with a sternal fracture were identified, 161 underwent screening with TnI and 104 with hsTnI. For TnI, the sensitivity and specificity for detection of clinically significant BCI was 0.80 and 0.79, respectively. For hsTnI, the sensitivity and specificity for detection of clinically significant BCI was 0.71 and 0.69, respectively. A multivariate analysis demonstrated the odds ratio for significant BCI with a positive TnI was 14.4 (95% confidence interval, 3.9-55.8, P < 0.0001) versus an odds ratio of 5.48 (95% confidence interval 1.9-15.7, P = 0.002) in the hsTnI group.
Conclusions:
The sensitivity of hsTnI is comparable to TnI for detection of significant BCI. Additional investigation is needed to determine the necessity and interval for repeat testing and the need for additional diagnostic testing.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Myocarditis II: Clinical Features and Diagnostic Tests
Angina III: Clinical Manifestations and Assessment