Purpose:
To investigate corneal densitometry and correlations with corneal morphological parameters in patients with bilateral keratoconus (KC) with unilateral Vogt's striae.
Methods:
This prospective contralateral study enrolled 112 patients (224 eyes) with evident KC characteristics (corneal topography with asymmetric bow-tie pattern, inferior steepening), and at least one KC sign (conical protrusion of the cornea at the apex, corneal stromal thinning, Fleischer ring, Vogt's striae) on slit-lamp examination. Corneal densitometry and morphological parameters were measured using Pentacam HR.
Results:
The mean age was 23.93 ± 6.81 years. Fifty-two (23.22%), 111 (49.55%), and 61 (27.23%) eyes were in mild, moderate, and severe groups, respectively. Corneal densitometry values of the anterior 0-2 mm and 2-6 mm, intermediate 0-2 mm and 2-6 mm, posterior 2-6 mm, and total cornea 2-6 mm were significantly higher in eyes with Vogt's striae (P < 0.05), whereas those of the anterior 6-10 mm, posterior 0-2 mm, and total cornea 6-10 mm were significantly lower in eyes with Vogt's striae (P < 0.05). Anterior 0-2 mm and total cornea 2-6 mm corneal densitometry values were positively correlated with anterior K1 (A-K1), K2 (A-K2), Km (A-Km), Kmax (A-Kmax), anterior corneal elevation, and posterior corneal elevation (P < 0.05), and negatively correlated with central corneal thickness and thinnest corneal thickness in eyes with Vogt's striae (P < 0.05). A-K2, A-Km, and A-Kmax were significantly correlated with the densitometry values of the anterior 0-2 mm and intermediate 0-2 mm in eyes without Vogt's striae (P < 0.05).
Conclusion:
Vogt's striae mainly occur on the anterior and intermediate layers during KC progression.
More Related Videos
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
12:36A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1
Published on: July 22, 2022
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment