A Semi-Self-Supervised Intrusion Detection System for Multilevel Industrial Cyber Protection

Fuchuan Ye1, Weiqiong Zhao2

  • 1Information and Educational Technology Center, Southwest Minzu University, Chengdu 610041, China.

Related Concept Videos

Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
299
Classification of Systems-II01:31

Classification of Systems-II

Continuous-time systems have continuous input and output signals, with time measured continuously. These systems are generally defined by differential or algebraic equations. For instance, in an RC circuit, the relationship between input and output voltage is expressed through a differential equation derived from Ohm's law and the capacitor relation,
218
Classification of Systems-I01:26

Classification of Systems-I

Linearity is a system property characterized by a direct input-output relationship, combining homogeneity and additivity.
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
278
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
124
Stereotype Content Model02:16

Stereotype Content Model

The Stereotype Content Model (SCM) was first proposed by Susan Fiske and her colleagues (Fiske, Cuddy, Glick & Xu, 2002; see also Fiske, 2012 and Fiske, 2017). The SCM specifies that when someone encounters a new group, they will stereotype them based on two metrics: warmth—or that group’s perceived intent, and how likely they are to provide help or inflict harm—and competence—or their ability to carry out that objective. Depending on the warmth-competence...
14.8K