Designed to Do Good: Key Findings on the Development and Operation of First Responder Deflection Programs

Jon Ross1, Bruce Taylor

  • 1TASC's Center for Health and Justice, Chicago, Illinois (Dr Ross); and NORC at The University of Chicago, Chicago, Illinois (Dr Taylor).

Related Concept Videos

Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
151
Cardiopulmonary Resuscitation III: AED Use01:23

Cardiopulmonary Resuscitation III: AED Use

Introduction to AEDAn Automated External Defibrillator (AED) is a portable medical device that analyzes the heart's rhythm and, if necessary, delivers an electrical shock to help the heart re-establish an effective rhythm during sudden cardiac arrest (SCA). SCA occurs when the heart suddenly and unexpectedly stops beating, leading to a loss of blood flow to the brain and other vital organs. In such emergencies, time is of the essence, and using an AED, combined with Cardiopulmonary...
53
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
128
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
137
Maximum Deflection01:13

Maximum Deflection

When analyzing beams under unsymmetrical loads, such as a train moving on a bridge, it is crucial to accurately determine the points of maximum stress and deflection. The process involves identifying the maximum deflection of the beam, which may not always occur at its midpoint due to the uneven distribution of the load.
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
593
Deflection of a Beam01:19

Deflection of a Beam

Accurately determining beam deflection and slope under various loading conditions in structural engineering is crucial for ensuring safety and structural integrity. Singularity functions offer a streamlined approach to analyzing beams, especially when multiple loading functions complicate the bending moment equation.
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
366