Related Experiment Video
Updated: Aug 26, 2025

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Donor neo-atrial cuff construction after accidental lower lobe vein transection
Raphael S Werner1, Claudio Caviezel1, Isabelle Opitz1
1Department of Thoracic Surgery, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Background:
An inadequate donor left atrial cuff is a rare technical issue after graft procurement for lung transplantation. With regard to the shortage of suitable donor organs for lung transplantation, these organs should be surgically reconstructed to avoid the loss of an organ and a futile intervention in the critically ill recipient.
Case Presentation:
We report a case of a 62-year old patient who underwent bilateral sequential lung transplantation for chronic obstructive pulmonary disease. During isolated lung procurement, the right inferior pulmonary vein was circumferentially transsected and separated from the right superior pulmonary and middle lobe veins. Subsequently, a reconstruction of the left atrial cuff with an acellular biological patch was performed to complete the atrium anastomosis. The patient experienced an uneventful postoperative recovery and a follow-up ventilation/perfusion scan showed normal perfusion of the right lower lobe.
Conclusions:
This case demonstrates that reconstruction of an inadequate left atrial cuff with a biological patch is feasible and allows for an adequate venous drainage and therefore normal transplant organ function.