Related Experiment Video
Updated: Aug 26, 2025

Uniportal Full Endoscopic Posterolateral Transforaminal Lumbar Interbody Fusion
Published on: June 6, 2025
Quasi-static loading of glass fiber-reinforced composite cervical fusion cage
Jaakko Luoma1, Ilkka Saarenpää1, Jaakko Rinne1
1Department of Neurosurgery, Division of Clinical Neurosciences, Turku University Hospital and University of Turku, Turku, Finland.
Objectives:
Anterior decompression and fusion in cervical spine has become one of the most common procedures in neurosurgery. In the surgery, cervical cage implants made of different biomaterials are used. Our purpose was to create a cervical cage made of glass fiber-reinforced composite (FRC) filled with bioactive glass particles and to characterize its behavior in quasi-static compression/shear stress loading conditions.
Materials And Methods:
FRC cages (n = 6) were manufactured with 2, 4, 6, 8 and 10 layers of glass fiber laminates and thermoset dimethacrylate resin matrix resulting in wall thickness from 0.70 to 2.1 mm. Control cage was a commercial PEEK cage (CeSpaceXP) implant with asymmetrical wall thickness of up 4.0 mm. Interior of the cage was filled with glass particles of the size 500-1250 μm simulating the bioactive glass which are used in FRC cranial implants. The FRC cages were quasi-statically loaded (compressive/shear stress) at a constant speed of 1 mm/min in the air.
Results:
The average yield strength force (YF) of the control PEEK cage was 3483.6 N (±134.3 N). The average YFs for tested FRC cage with 2, 4, 6, 8 and 10 layers of FRC fabric varied from 1336.5 N (±403.8 N) to 7675.0 N (±670.0 N), respectively. The average ultimate forces (UF) for tested FRC cages varied from 1535.8 N (±406.2 N) to 9975.0 N (±1492.4 N). With six layers of FRC fabric, YF of the FRC cage was comparable to the PEEK implants.
Conclusions:
In this study, it was demonstrated that it is possible to manufacture a cervical interbody fusion device made of FRC and filled with bioactive glass with proper load bearing capacities. Because of physical properties of FRC-bioactive glass, the FRC cage might have some advances compared to the state-of-the-art cages, like faster bony union and smaller rate of subsidence, which will be studied in the future.
More Related Videos
Related Concept Videos
Fiber Reinforced Concrete
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...

