Related Experiment Video
Updated: Aug 26, 2025

Modeling Brain Metastases Through Intracranial Injection and Magnetic Resonance Imaging
Published on: June 7, 2020
Gradual Self-Training via Confidence and Volume Based Domain Adaptation for Multi Dataset Deep Learning-Based Brain
Andrea Liew1, Chun Cheng Lee2, Valarmathy Subramaniam2
1Electrical and Computer Systems Engineering Discipline, School of Engineering, Monash University Malaysia, Bandar Sunway, Malaysia.
Background:
Research suggests that treatment of multiple brain metastases (BMs) with stereotactic radiosurgery shows improvement when metastases are detected early, providing a case for BM detection capabilities on small lesions.
Purpose:
To demonstrate automatic detection of BM on three MRI datasets using a deep learning-based approach. To improve the performance of the network is iteratively co-trained with datasets from different domains. A systematic approach is proposed to prevent catastrophic forgetting during co-training.
Study Type:
Retrospective.
Population:
A total of 156 patients (105 ground truth and 51 pseudo labels) with 1502 BM (BrainMetShare); 121 patients with 722 BM (local); 400 patients with 447 primary gliomas (BrATS). Training/pseudo labels/validation data were distributed 84/51/21 (BrainMetShare). Training/validation data were split: 121/23 (local) and 375/25 (BrATS).
Field Strength/Sequence:
A 5 T and 3 T/T1 spin-echo postcontrast (T1-gradient echo) (BrainMetShare), 3 T/T1 magnetization prepared rapid acquisition gradient echo postcontrast (T1-MPRAGE) (local), 0.5 T, 1 T, and 1.16 T/T1-weighted-fluid-attenuated inversion recovery (T1-FLAIR) (BrATS).
Assessment:
The ground truth was manually segmented by two (BrainMetShare) and four (BrATS) radiologists and manually annotated by one (local) radiologist. Confidence and volume based domain adaptation (CAVEAT) method of co-training the three datasets on a 3D nonlocal convolutional neural network (CNN) architecture was implemented to detect BM.
Statistical Tests:
The performance was evaluated using sensitivity and false positive rates per patient (FP/patient) and free receiver operating characteristic (FROC) analysis at seven predefined (1/8, 1/4, 1/2, 1, 2, 4, and 8) FPs per scan.
Results:
The sensitivity and FP/patient from a held-out set registered 0.811 at 2.952 FP/patient (BrainMetShare), 0.74 at 3.130 (local), and 0.723 at 2.240 (BrATS) using the CAVEAT approach with lesions as small as 1 mm being detected.
Data Conclusion:
Improved sensitivities at lower FP can be achieved by co-training datasets via the CAVEAT paradigm to address the problem of data sparsity.
Level Of Evidence:
3 TECHNICAL EFFICACY STAGE: 2.
More Related Videos
07:15Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
09:53Quantifying the Brain Metastatic Tumor Micro-Environment using an Organ-On-A Chip 3D Model, Machine Learning, and Confocal Tomography
Published on: August 16, 2020
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Magnetic Resonance Imaging