Related Experiment Video
Updated: Aug 25, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Effect of Radiocapitellar Joint Over/Under Stuffing on Elbow Joint Contact Pressure
Taghi Ramazanian1, Julia A Müller-Lebschi1, Marie-Caroline H Merlet2
1Biomechanics Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Purpose:
Comminuted radial head fractures are commonly treated by surgical resection or replacement with a prosthesis. A potential problem with radial head replacement is overlengthening of the radial neck ("overstuffing" of the radial head), which has been shown to affect both ulnohumeral kinematics and radiocapitellar pressures. We hypothesized that an overstuffed radial head prosthesis increases capitellar pressure and reduces coronoid pressure.
Methods:
Seven human cadaveric elbows were prepared on a custom-designed apparatus simulating stabilizing muscle loads, and passively flexed from 0° to 90° under gravity valgus torque while joint contact pressures were measured. Each elbow was tested sequentially with different neck lengths, starting with the intact specimen followed by insertion of understuffed (-2 mm), standard-height (0 mm), and overstuffed (+2 mm) radial head prostheses in neutral forearm rotation, 40° pronation, and 40° supination positions, respectively.
Results:
Capitellar mean contact pressures significantly increased after insertion of an overstuffed radial head prosthesis. In valgus position with neutral forearm rotation, capitellar mean contact pressure on the joint with an intact radial head averaged 227 ± 70 kPa. Insertion of understuffed, standard-height, and overstuffed radial head prostheses changed the mean contact pressures to 152 ± 76 kPa, 212 ± 68 kPa, and 491 ± 168 kPa, respectively. The overstuffed radial head group had significantly lower whole coronoid mean contact pressures (153 ± 56 kPa) compared with the intact (390 ± 138 kPa) and standard-height (376 ± 191 kPa) radial head groups.
Conclusions:
An increase in radial prosthesis height significantly increases capitellar contact pressures and reduces coronoid contact pressures.
Clinical Relevance:
Restoration of the anatomic radial head height is critical when performing radial head arthroplasty to maintain normal joint biomechanics. Elevated capitellar contact pressures can potentially lead to pain and early degenerative changes.
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Humerus
Impact Loading
In cases of elastic deformation,...
Applications of Stress
The...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...

