Related Experiment Video
Updated: Aug 25, 2025

Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Demarcation Line Depth in Epithelium-Off Corneal Cross-Linking Performed at the Slit Lamp
Farhad Hafezi1,2,3,4,5, Nan-Ji Lu2,5,6, Jad F Assaf7
1Laboratory for Ocular Cell Biology, Center for Applied Biotechnology and Molecular Medicine, University of Zurich, 8006 Zurich, Switzerland.
Abstract:
We aimed to evaluate the depth of the demarcation line following accelerated epithelium-off corneal cross-linking (A-CXL) performed at the slit lamp with the patient sitting in an upright position. Twenty-three eyes from twenty patients, undergoing epi-off A-CXL (9 mW/cm2 for 10 min) using a CXL device at the slit lamp in the upright position. Demarcation line depth was assessed at 1 month after the procedure using anterior segment optical coherence tomography (AS-OCT) and specialized software. Surgery was uneventful in all cases. The average postoperative demarcation line depth achieved was 189.4 µm (standard deviation: 58.67 µm). The demarcation line depth achieved with patients sitting upright, receiving CXL at the slit lamp, is similar to published data on CXL performed in the supine position, suggesting that demarcation line depth is not dependent on patient orientation during CXL.