Related Experiment Video
Updated: Aug 25, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Parametric Study of the Numerical Model of a Bolted Connection of Steel Structure for Photovoltaic Panels
Damian Mrówczyński1, Tomasz Gajewski2, Tomasz Garbowski3
1Doctoral School, Department of Biosystems Engineering, Poznan University of Life Sciences, Wojska Polskiego 28, 60-637 Poznań, Poland.
Abstract:
In the face of the reality that unexpectedly mobilized the governments of most central European countries (including Poland), the development of renewable energy sources (RES) seems to be an important direction. Therefore, both wind parks and solar farms will be constructed at double speed for energetic independence. This urgency makes the market of producers of structures for mounting solar panels also need to adapt quickly to the new situation. New constructions adapted to quick assembly with the use of nutless screw connections seem to be one of the best solutions. These structures must not only be easy and quick to install but also durable, which makes the connections resistant to cyclical loads. The speed of assembly of the substructure can be achieved precisely with the help of nutless connections, but their durability should be carefully analyzed. This article presents parametric analyses of the numerical model of this type of connection. The selection of appropriate numerical models for simulation is of key importance in the fatigue strength analysis of bolted connections. This article investigates two different models used in numerical fatigue analyses performed in the Abaqus FEA and FE-Safe program, namely, traditional bolt with nut and innovative self-tapping nutless bolt. Extended parametric analyses of both numerical models were carried out, which ultimately allowed optimization of the fatigue capacity of the connection.
Related Concept Videos
Design of Prismatic Beams for Bending
Shear and Bending Moment Diagram: Problem Solving
Draw a Free-Body Diagram: Start by drawing a free-body diagram of the entire beam, including the concentrated loads, distributed load, and reaction...
Design of Transmission Shafts - Stress Analysis
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Applications of Stress
The...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...