Related Experiment Video
Updated: Aug 25, 2025

A Random-displacement Measurement by Combining a Magnetic Scale and Two Fiber Bragg Gratings
Published on: September 30, 2019
A Double FBGs Temperature Self-Compensating Displacement Sensor and Its Application in Subway Monitoring
Hongli Li1,2, Gang Xu1,3, Xin Gui3
1School of Mechanical Engineering, Hubei Engineering University, Xiaogan 432100, China.
Abstract:
In order to ensure the effective vibration-reduction and vibration-isolation of the steel spring floating plate rail and meet the safe operation requirements of the subway, a Fiber Bragg Grating (FBG) displacement sensor for the deformation monitoring of the subway floating plate is proposed. The sensor adopts double FBGs to realize temperature self-compensation. The elastic ring is used as the elastic conversion structure after the fiber grating is pre-stretched; the two ends are pasted and fixed in the groove in the diameter direction of the ring, which avoids the waveform distortion caused by the full pasting of the fiber grating. The combination of linear bearing and displacement probe rods can increase stability and reduce friction loss so that the sensor has the advantages of high sensitivity and accurate measurement results. The test results and error analysis show that in the range of 0~20 mm, the sensitivity of the sensor is 164.2 pm/mm, the accuracy reaches 0.09% F.S, and the repeatability error and hysteresis error are only 1.86% and 0.99%, respectively. The thermal displacement coupling experiment proves that the sensor has good temperature self-compensation performance. It provides a new technical scheme for the effective monitoring and condition assessment of the built-in steel spring floating plate rail.
More Related Videos
Related Concept Videos
Distance Corrections
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Electronic Distance Measuring Instruments

