Related Experiment Video
Updated: Aug 25, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Experimental and Numerical Study of Static Behavior of Precast Segmental Hollow Bridge Piers
Wenliang Lu1, Wen-Qiang Peng1, Li Zhu1
1School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China.
Abstract:
To investigate the static performance of precast segmental hollow piers, two precast segmental hollow pier specimens were designed for static loading tests on the top of piers. The finite element model of precast segmental hollow piers was established by the finite element software Abaqus and verified based on the test results. Based on the experimental and finite element models, three optimal design solutions were proposed, and the calculation results of each solution were analyzed. The results show that precast segmental hollow pier mechanical behavior is similar to that of cantilevered bending members. The specimens present brittle damage characteristics after the destruction of the structure at the bottom of the pier pressure edge as the axis of the rigid body rotation. Following the test loading process, the bonding between the segments is good, except for the pier bottom damage surface of the rest of the bonding surface, which has no relative displacement. The calculation results of the finite element model are in good agreement with the test results and can effectively predict the load-displacement response of precast piers. Three optimized design solutions are proposed. The finite element simulation proves all three optimized design solutions show better overall ductility than the original solution and can effectively improve the performance of segmental precast hollow piers.
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Prestressed Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Design of Prismatic Beams for Bending
Indeterminate Structure
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...