Related Experiment Video
Updated: Aug 25, 2025

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Impact of implementing the aseptic compounding management system, Medcura, on internal error rates within an oncology
Emily Smith1, Andy Fox2, Graeme Willmers2
1Pharmacy, University Hospital Southampton NHS Foundation Trust, Southampton, UK emily.smith@uhs.nhs.uk.
Background:
As cancer survivorship improves, pressure on oncology services to provide safe, timely treatments increases. Traditional manual compounding processes are error prone, putting patients at risk. Additionally, errors have a detrimental impact on service delivery and staff morale. Information technology is increasingly utilised to improve safety and service delivery of systemic anti-cancer therapy (SACT). The compounding process control system, Medcura, was developed to manage the end-to-end process and reduce transcription and calculation errors.
Objectives:
To evaluate the impact of implementing Medcura on internal errors and staff perceptions of errors.
Method:
An aseptic process control system, Medcura, was implemented in a busy pharmacy chemotherapy production unit. Internal error and severity data were collected and analysed for 14 months before and during implementation, and 24 months after implementation. In addition, one-to-one semi-structured interviews were carried out with pharmacy staff, pre- and post-implementation. Interviews were transcribed and thematically analysed.
Results:
Error rates decreased after implementation from 2.9% to 2.1%. The types of error detected also changed with a decrease in worksheet and labelling errors, and an increase in assembly errors. The severity of the errors, as a percentage of total errors made, also decreased after implementation. Staff were predominantly positive about Medcura; it reduced the number of errors, eased the preparation of worksheets and labels, reduced pressure and work-related stress, and improved job satisfaction.
Conclusions:
Implementing Medcura has resulted in a reduction in both error rate and severity. Specifically, errors related to label and worksheet generation have seen the largest reduction. Staff have viewed these changes positively and report reduced levels of work-related stress. Further development and roll-out will improve patient safety and staff morale.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Errors occurring during blood pressure monitoring
Several factors...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Asepsis