Related Experiment Video
Updated: Aug 25, 2025

Detection and Isolation of Cancer in Prostate Biopsies Using Stimulated Raman Histology and Artificial Intelligence
Published on: June 10, 2025
Inter-reader agreement of the prostate imaging reporting and data system version v2.1 for detection of prostate
Jing Wen1, Yugang Ji2, Jing Han3
1Department of Medical Imaging, Jiangsu Vocational College of Medicine, Yancheng, China.
Objectives:
We aimed to systematically assess the inter-reader agreement of the Prostate Imaging Reporting and Data System Version (PI-RADS) v2.1 for the detection of prostate cancer (PCa).
Methods:
We included studies reporting inter-reader agreement of different radiologists that applied PI-RADS v2.1 for the detection of PCa. Quality assessment of the included studies was performed with the Guidelines for Reporting Reliability and Agreement Studies. The summary estimates of the inter-reader agreement were pooled with the random-effect model and categorized (from slight to almost perfect) according to the kappa (κ) value. Multiple subgroup analyses and meta-regression were performed to explore various clinical settings.
Results:
A total of 12 studies comprising 2475 patients were included. The pooled inter-reader agreement for whole gland was κ=0.65 (95% CI 0.56-0.73), and for transitional zone (TZ) lesions was κ=0.62 (95% CI 0.51-0.72). There was substantial heterogeneity presented throughout the studies (I 2= 95.6%), and meta-regression analyses revealed that only readers' experience (<5 years vs. ≥5 years) was the significant factor associated with heterogeneity (P<0.01). In studies providing head-to-head comparison, there was no significant difference in inter-reader agreement between PI-RADS v2.1 and v2.0 for both the whole gland (0.64 vs. 0.57, p=0.37), and TZ (0.61 vs. 0.59, p=0.81).
Conclusions:
PI-RADS v2.1 demonstrated substantial inter-reader agreement among radiologists for whole gland and TZ lesions. However, the difference in agreement between PI-RADS v2.0 and v2.1 was not significant for the whole gland or the TZ.