Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Acute Kidney Injury IV: Diagnostic Studies and Prevention01:30

Acute Kidney Injury IV: Diagnostic Studies and Prevention

53
Accurate diagnosis and effective prevention are critical in managing Acute Kidney Injury (AKI), which is linked to high mortality rates ranging from 10% to 80%. Timely recognition of at-risk patients and careful monitoring can significantly reduce the likelihood of kidney damage.Diagnostic Assessments:The diagnostic process starts with a comprehensive medical history to identify prerenal, intrarenal, and postrenal causes.Prerenal causes, such as dehydration, hypotension, or blood loss, should...
53
Assessing Body Temperature - Rectal01:27

Assessing Body Temperature - Rectal

5.9K
Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
5.9K
Temperature Measurement Sites01:14

Temperature Measurement Sites

2.0K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
2.0K
Assessing Body Temperature - Oral01:14

Assessing Body Temperature - Oral

810
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
810
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

1.6K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.6K
Diagnosing Acidosis and Alkalosis01:24

Diagnosing Acidosis and Alkalosis

469
Diagnosing acid-base imbalances involves systematically analyzing arterial blood samples, focusing on three key measurements: pH, bicarbonate (HCO3−) concentration, and carbon dioxide partial pressure (PCO2). This analysis follows a four-step process that helps identify the imbalance's underlying cause and nature.
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2  and...
469

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pediatric firearm risk prediction in trauma centers and after discharge: A machine learning analysis.

Journal of pediatric surgery·2026
Same author

Trends in nitrous oxide abuse and misuse: a 22-year analysis of United States poison center data.

Clinical toxicology (Philadelphia, Pa.)·2025
Same author

Pediatric Window Falls: Factors Related to Clinical Outcomes Within a State Trauma Registry.

The Journal of emergency medicine·2025
Same author

Geospatial Clustering of 9-1-1 Responses for Pediatric Firearm Injuries Over Time.

Pediatrics·2025
Same author

EMS Agency Characteristics and Adverse Events in Pediatric Out-of-Hospital Cardiac Arrest Among 49 U.S. EMS Agencies.

Prehospital emergency care·2025
Same author

Virtual Neonatal Resuscitation Curriculum for Emergency Medical Services (EMS) to Improve Out-of-Hospital Newborn Care.

Prehospital emergency care·2025

Related Experiment Video

Updated: Aug 25, 2025

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
07:48

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock

Published on: October 28, 2022

1.3K

Point-of-Care Noninvasive Technology for Pediatric Dehydration Assessment.

David C Sheridan1, Guillermo A Kohn-Loncarica2, Pedro Nunez2

  • 1From the Department of Emergency Medicine, Oregon Health and Science University, Portland, OR.

Pediatric Emergency Care
|October 17, 2022
PubMed
Summary

A new digital capillary refill device shows promise for diagnosing dehydration in children. Combined with patient factors, it may improve early detection and treatment of pediatric dehydration.

More Related Videos

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
09:32

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge

Published on: January 20, 2023

3.6K
Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
06:55

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing

Published on: May 8, 2021

5.6K

Related Experiment Videos

Last Updated: Aug 25, 2025

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
07:48

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock

Published on: October 28, 2022

1.3K
Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
09:32

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge

Published on: January 20, 2023

3.6K
Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
06:55

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing

Published on: May 8, 2021

5.6K

Area of Science:

  • Pediatric Emergency Medicine
  • Point-of-Care Diagnostics
  • Dehydration Assessment

Background:

  • Dehydration is a global health issue, particularly in children.
  • Current clinical dehydration assessment methods in children are subjective and rely on provider expertise.
  • There is a need for objective, noninvasive tools to diagnose dehydration in pediatric patients.

Purpose of the Study:

  • To evaluate a novel noninvasive, point-of-care technology for diagnosing dehydration in children.
  • To assess the accuracy of a digital capillary refill device combined with patient factors in identifying dehydration.
  • To explore the utility of this technology in a clinical setting for timely intervention.

Main Methods:

  • Prospective observational study conducted at a tertiary care children's hospital.
  • Included children under 10 presenting with vomiting/diarrhea deemed potentially dehydrated.
  • Utilized a digital capillary refill device alongside standard vital signs and serial weight measurements.

Main Results:

  • The study analyzed 56 children, with malnutrition, temperature, and systolic blood pressure selected for the multivariable model (AUC=0.7431).
  • Excluding blood pressure, the model retained good performance (AUC=0.7269), suggesting utility in settings without blood pressure monitoring.
  • The findings indicate a fair predictive capability for the device and associated factors.

Conclusions:

  • A digital capillary refill point-of-care device, when used with patient-specific factors, may enhance pediatric dehydration detection.
  • This technology has the potential to facilitate earlier treatment decisions and appropriate escalation of care.
  • The findings support the development of objective tools for managing pediatric dehydration.