Ultrasound Assessment of Spastic Muscles in Ambulatory Chronic Stroke Survivors Reveals Function-Dependent Changes
Javier González-Buonomo1, Alexander H Pham2, Jaskiran Ghuman3
1Department of Physical Medicine and Rehabilitation, McGovern Medical School, The University of Texas Health Science Center, and TIRR Memorial Hermann Hospital, Houston, TX, USA; Hospital de la Concepción San German, and Multy Medical Facilities, Ponce, Puerto Rico.
Objective:
To correlate ultrasound characteristics of spastic muscles with clinical and functional measurements in chronic stroke survivors.
Methods:
Ultrasound assessment and clinical and functional assessments were performed in 28 ambulatory stroke survivors (12 females, mean age 57.8 ± 11.8 years, 76 ± 45 months after stroke).
Results:
Muscle thickness in the affected side was decreased compared with the contralateral side (p < 0.001). The decrease was more evident in the upper limb muscles. On the affected side, the modified Heckmatt scale score was lowest (closer to normal) in the rectus femoris (RF) muscle compared with other muscles (biceps brachii (BB), flexor carpi ulnaris (FCU) and medial gastrocnemius (MG)). Muscle thickness and echogenicity of spastic muscles did not correlate with spasticity, as measured with the modified Ashworth scale (MAS), Fugl-Meyer motor assessment scores, age, or time since stroke. There was a significant negative correlation between grip strength and percentage decrease in muscle thickness for the spastic FCU muscle (r = -0.49, p = 0.008). RF muscle thickness correlated with ambulatory function (Timed Up and Go test (r = 0.44, p = 0.021) and 6-metre walk test (r = 0.41, p = 0.032)). There was no significant correlation between echogenicity and functional assessments Conclusion: Ambulatory chronic stroke survivors had function-dependent changes in muscle thickness on the affected side. Muscle thickness and echogenicity of spastic muscles did not correlate with spasticity, Fugl-Meyer motor assessment scores, age, or time since stroke.