Related Experiment Video
Updated: Aug 25, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Long short-term memory network of machine learning for compensating temperature error of a fiber optic gyroscope
Abstract:
We present an artificial intelligence compensation method for temperature error of a fiber optic gyroscope (FOG). The difference from the existing methods is that the compensation model finally determined by this method only uses the FOG's data to complete the regression prediction of the temperature error and eliminate the dependency on the temperature sensor. In the experimental stage, the proposed method performs temperature experiments with three varying trends of temperature heating, holding, and cooling and obtains sufficient output data sets of the FOG. Taking the output time series of the FOG as the input sample and based on the long short-term memory network of machine learning, the training, validation, and test of the model are completed. From the two perspectives of network learning ability and the improvement degree of the FOG's performance, four indicators, including root mean square error, error cumulative distribution function, FOG bias stability, and Allan variance analysis are selected to evaluate the performance of the compensation model comprehensively. Compared with the existing methods using temperature information for prediction and compensation, the results show that the error compensation method without temperature information proposed can effectively improve the accuracy of the FOG and reduce the complexity of the compensation system. The work can also provide technical references for error compensation of other sensors.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Dependent Deformation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Gyroscope

