The Council Directive 2013/59/Euratom has introduced binding requirements for the management of radon in the workplace in Member States of the European Union. How does it work in practice? In 2021, the European ALARA Network created a working group on ALARA for Radon at Work with the objective of collecting and sharing experiences from the field. A survey was developed to detail each step of the national regulations for the control of radon and to describe case studies showing implementation. This article presents a qualitative analysis of the answers received from seven countries. There are no two similar national regulations and, at each step, different provisions, protocols, techniques etc are applicable or recommended. This diversity contributes to the richness of the results and can inform about interesting and good practices, where 'good' is defined by what is appropriate in the nationally and locally prevailing circumstances. All national regulations follow a graded approach, which is a key component for the implementation of the optimisation (ALARA) principle, yet several potential weak points that may be challenging to ALARA have been identified and are discussed, namely the radon risk assessment, the focus on numerical values, uncertainties in the measurement, how to obtain economically efficient remediation, and the interface with other regulations. Strengthening collaboration between risk prevention and radiation protection actors could help to provide and build expertise on radon management in the workplace, especially when exposure is managed as a planned exposure situation.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiation: Applications
The average...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...