Related Experiment Video
Updated: Aug 24, 2025

Fabrication of Mechanically Tunable and Bioactive Metal Scaffolds for Biomedical Applications
Published on: December 8, 2015
Enhanced corrosion resistance in an inflammatory environment and osteogenic properties of silicalite-1 coated
Junyan Wang1, Mingrui Li2, Ruining Shi3
1Department of Dental Implantology, Hospital of Stomatology, Jilin University, Changchun 130021, China; Jilin Provincial Key Laboratory of Tooth Development and Bone Remodeling, Changchun 130021, China.
Abstract:
The corrosion resistance and osteogenic property of titanium-based implants are crucial for their clinical application. Although they have good stability in standard physiological solutions, limited corrosion resistance in the inflammatory environment is still an unavoidable problem. Herein, the calcined and uncalcined silicalite-1 coatings were synthesized on titanium alloy (Ti-6Al-4 V). The corrosion resistance was investigated by simulating an inflammatory environment in vitro, and osteogenic potential was also evaluated. Here, the uncalcined silicalite-1 coating had the highest corrosion protection efficiency (PE) for Ti-6Al-4 V, which inhibited the metal ion release, surface damage and mass loss in the short-term (7 days) and long-term (30 days). Moreover, positive cell responses, including adhesion, proliferation and osteogenic differentiation of MC3T3-E1 cells, were observed in the uncalcined silicalite-1 coating system, supporting its favorable biocompatibility and osteogenic property. Therefore, these findings indicate that the uncalcined silicalite-1 may be a promising coating strategy for the surface modification of Ti-6Al-4 V implants.