Related Experiment Video
Updated: Aug 24, 2025

Photoacoustic Cystography
Published on: June 11, 2013
Towards in vivo applications of 111Ag perturbed angular correlation of γ-rays (PAC) spectroscopy
Marianna Tosato1, Mattia Asti2, Valerio Di Marco1
1Department of Chemical Sciences, University of Padova, via Marzolo 1, 35131, Padova, Italy.
Abstract:
111Ag-perturbed angular correlation of γ-rays (PAC) spectroscopy provides information on the nuclear quadrupole interactions, and thereby on the local structure and dynamics of the silver ion binding site. Brownian rotational motion, i.e. rotational diffusion, of 111Ag-labeled molecules will significantly affect the PAC spectra. Here we illustrate this effect, by simulating 111Ag PAC spectra for 111Ag-labeled molecules with molecular masses spanning from 102 to 106 g/mol, reflecting a span from fast (small molecules) to slow (large molecules) rotational diffusion on the PAC time scale. The simulated spectra are compared to 111Ag-PAC data obtained from a pilot study involving 111Ag(I) bound to a designed chelator exhibiting fast reorientation in solution, as well as to 111Ag-labeled species formed by 111Ag(I) in human serum, exhibiting slow (or no) reorientation on the PAC time scale. The simulated and experimental data illustrate typical PAC signals that are likely to be observed in vivo, when following the fate of 111Ag-labeled compounds. Potential in vivo applications are stability studies of 111Ag-radiopharmaceuticals, dissociation studies of 111Ag from the labeled molecule followed by binding to another (bio)molecule, or binding of 111Ag-labeled probes to larger carriers such as proteins.
More Related Videos
06:46Pulsed Laser Diode-Based Desktop Photoacoustic Tomography for Monitoring Wash-In and Wash-Out of Dye in Rat Cortical Vasculature
Published on: May 30, 2019
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...