Development of Pressure Sensor Based Wearable Pulse Detection Device for Radial Pulse Monitoring
Shihang Wang1, Zhinan Zhang1, Zhijian Chen1
1Key Laboratory of Advanced Manufacturing Technology of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
Abstract:
Wearable pulse detection devices can be used for daily human healthcare monitoring; however, the relatively poor flexibility and low sensitivity of the pulse detection devices are hindering the scrutiny of pulse information during pulse diagnosis of different pulse positions. This paper developed a novel and wearable pulse detection device based on three flexible pressure sensors using synthetic graphene and silver composites as the pressure sensing material. The structural design of the pulse detection device is firstly presented; the core component of pressure sensors is using the sawtooth protrusions to convert pressure induced by radial pulse vibrations into localized deformation of graphene composites. The fabricated pulse detection device is characterized by high pressure sensing performance, including relatively high sensitivity (8.65% kPa-1), broad sensing range (12 kPa), and good dynamic response with a response time of about 100 ms. Then, the pulse detection device is worn on a human wrist to detect the pulses from three pulse positions, namely, 'Cun', 'Guan', and 'Chi', and the results demonstrated the capability of using our device to detect pulse signals. The physical conditions of the subject, such as arterial stiffness index, can be further analyzed through the characteristics of the acquired pulse signals, demonstrating the potential application of using wearable pulse detection devices for human health monitoring.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse