Related Experiment Video
Updated: Aug 23, 2025

Deep Neural Networks for Image-Based Dietary Assessment
Published on: March 13, 2021
Non-invasive blood pressure estimation combining deep neural networks with pre-training and partial fine-tuning
Ziyan Meng1,2, Xuezhi Yang1,2, Xuenan Liu1,2
1School of Computer and Information, Hefei University of Technology, Hefei 230009, People's Republic of China.
Abstract:
Objective. Daily blood pressure (BP) monitoring is essential since BP levels can reflect the functions of heart pumping and vasoconstriction. Although various neural network-based BP estimate approaches have been proposed, they have certain practical shortcomings, such as low estimation accuracy and poor model generalization. Based on the strategy of pre-training and partial fine-tuning, this work proposes a non-invasive method for BP estimation using the photoplethysmography (PPG) signal.Approach. To learn the PPG-BP relationship, the deep convolutional bidirectional recurrent neural network (DC-Bi-RNN) was pre-trained with data from the public medical information mark for intensive care (MIMIC III) database. A tiny quantity of data from the target subject was used to fine-tune the specific layers of the pre-trained model to learn more individual-specific information to achieve highly accurate BP estimation.Main results.The mean absolute error and the Pearson correlation coefficient (r) of the proposed algorithm are 3.21 mmHg and 0.919 for systolic BP, and 1.80 mmHg and 0.898 for diastolic BP (DBP). The experimental results show that our method outperforms other methods and meets the requirements of the Association for the Advancement of Medical Instrumentation standard, and received an A grade according to the British Hypertension Society standard.Significance.The proposed method applies the strategy of pre-training and partial fine-tuning to BP estimation and verifies its effectiveness in improving the accuracy of non-invasive BP estimation.
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

