Intrarenal Doppler approaches in hemodynamics: A major application in critical care
Xiaoling Qian1,2, Junhai Zhen2, Qingxiang Meng3
1The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, China.
Abstract:
The treatment of severe cases usually requires multimodality hemodynamic monitoring approaches, particularly for tissue and organ perfusion tracking. Currently, only a few studies have investigated renal perfusion status at the bedside. Ultrasound has become increasingly utilized to guide the hemodynamic management of severe patients. Similarly, intrarenal Doppler (IRD) is widely used to assess renal perfusion from both the intrarenal artery and vein perspectives. The renal resistive index (RRI), which reflects the renal arterial blood flow profile, is often applied to predict the reversibility of renal dysfunction and to titrate hemodynamic support. Intrarenal venous flow (IRVF) patterns and the renal venous stasis index (RVSI), which reflects the intrarenal vein blood flow profile, are now being used to assess intravenous congestion. They may also be useful in predicting the risk of acute kidney injury and avoiding fluid overload. IRD can provide diverse and supplemental information on renal perfusion and may help to establish the early diagnosis in severe patients. This review focused on the specific operational methods, influencing factors, and applications of IRD in hemodynamics.
More Related Videos
06:38Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Continuous Renal Replacement Therapy
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Hemodialysis I: Introduction
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Acute Kidney Injury V: Interprofessional Care