Related Experiment Video
Updated: Aug 23, 2025

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Ion exchange chromatography hyphenated with fluorescence detector as a sensitive alternative to UV detector:
Srishti Joshi1, Kratika Upadhyay1, Anurag S Rathore1
1Department of Chemical Engineering, IIT Delhi, Hauz Khas, New Delhi 110016, India.
Abstract:
Cation-exchange chromatography (CEX) is widely used for analysis of charge heterogeneity in monoclonal antibodies (mAbs) in the biopharmaceutical industry. Charge variant separation is typically achieved by either alteration of ionic strength or pH, and detection of the various species is performed using diode array detectors (DAD) at 280 nm. In this study, we investigate the suitability of fluorescence detector (FLD) as a sensitive alternative to traditional UV280 detection-based charge variant analysis. The objective of this work is to compare the performance of charge variants detection through cation exchange chromatography between FLD and DAD detectors. This was demonstrated for a mass spectroscopy compatible, pH based CEX method utilizing volatile ammonium acetate salt. The stability of FLD detection was tested as per method validation criteria set in the ICH Q2-(R1). LODFLD and LOQFLD were 59.07 and 59.64 times lower in comparison to LODUV and LOQUV, respectively (LODFLD: 0.13 µg, LOQFLD: 0.39 µg). The LinearityFLD was obtained in the range of 1-200 µg. Accuracy calculated as recovery value was between 93.38% and 103.35% and highest RSD value obtained for robustness was 2.54% (area under the curve). The application of FLD detection based CEX as a Process Analytical Technology (PAT) enabler in mAb biopharmaceutical analysis was demonstrated through direct charge variant profiling of CHO cell harvest supernatant (without pre purification through Pro-A). The method was also applied to and found suitable for biosimilarity assessment of drug products. While the present study is focused on analysis of trastuzumab biosimilars, the proposed method is expected to be applicable to any mAb product after suitable gradient modification.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
UV–Vis Spectrometers
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Photoluminescence: Applications

