Related Experiment Video
Updated: Aug 22, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Development and evaluation of a standardized technique to assess teat skin temperature of dairy cows using infrared
C DiLeo1, P S Basran2, I R Porter2
1College of Veterinary Medicine, Cornell University, Ithaca, NY 14853.
Much research has been done to develop methods to assess dimensional teat traits in dairy cows. In contrast, diagnostic techniques to reliably assess the circulatory system of teats are limited. Infrared thermography facilitates measurements of skin temperature and could be used to detect physiological and pathological changes to the teat tissue associated with machine milking, as temperature reflects the underlying blood circulation and tissue metabolism. Our objective was to develop and evaluate a scanning technique to quantify teat skin temperature in dairy cows using infrared thermography. Using a portable thermography camera, 2 operators obtained duplicate scans of both hind teats from 20 Holstein cows, resulting in 80 thermographic images (20 cows × 2 operators × 2 images). Average teat skin temperatures at the proximal, middle, and distal teat aspects were determined. We used Pearson correlation coefficients (r), intraclass correlation coefficients (ICC), and concordance correlation coefficients (CCC) to assess interoperator reproducibility (i.e., agreement between measurements performed by different operators) and intraoperator repeatability (i.e., agreement between measurements performed by the same operator). Pearson correlation coefficients revealed a very strong correlation for measurements at the proximal, middle, and distal aspects of the teat, respectively, between operators (r ≥0.95) and duplicate scans (r ≥0.94) within operators. Intraclass correlation coefficients and CCC indicated excellent interoperator reproducibility (ICC ≥0.95, CCC ≥0.95) and excellent intraoperator repeatability (ICC ≥0.94, CCC ≥0.94), respectively, for measurements at all 3 aspects. Least squares means (95% confidence interval) for average teat skin temperatures at the proximal, middle, and distal teat aspects, respectively, were 33.2 (32.6-33.8), 32.4 (31.5-33.2), and 30.9 (29.8-32.0) °C for operator 1, and 33.2 (32.6-33.8), 32.4 (31.6-33.3), and 31.0 (29.9-32.0) °C for operator 2. Average temperatures between duplicate scans within operators at the proximal, middle, and distal aspects, respectively, were 33.3 (32.7-33.9), 32.5 (31.7-33.3), and 31.0 (29.9-32.1) °C for the first scan and 33.2 (32.6-33.8), 32.3 (31.5-33.1), and 30.8 (29.7-31.9) °C for the second scan. We conclude that infrared thermography facilitates precise measurements of skin temperatures of cows' hind teats.
Much research has been done to develop methods to assess dimensional teat traits in dairy cows. In contrast, diagnostic techniques to reliably assess the circulatory system of teats are limited. Infrared thermography facilitates measurements of skin temperature and could be used to detect physiological and pathological changes to the teat tissue associated with machine milking, as temperature reflects the underlying blood circulation and tissue metabolism. Our objective was to develop and evaluate a scanning technique to quantify teat skin temperature in dairy cows using infrared thermography. Using a portable thermography camera, 2 operators obtained duplicate scans of both hind teats from 20 Holstein cows, resulting in 80 thermographic images (20 cows × 2 operators × 2 images). Average teat skin temperatures at the proximal, middle, and distal teat aspects were determined. We used Pearson correlation coefficients (r), intraclass correlation coefficients (ICC), and concordance correlation coefficients (CCC) to assess interoperator reproducibility (i.e., agreement between measurements performed by different operators) and intraoperator repeatability (i.e., agreement between measurements performed by the same operator). Pearson correlation coefficients revealed a very strong correlation for measurements at the proximal, middle, and distal aspects of the teat, respectively, between operators (r ≥0.95) and duplicate scans (r ≥0.94) within operators. Intraclass correlation coefficients and CCC indicated excellent interoperator reproducibility (ICC ≥0.95, CCC ≥0.95) and excellent intraoperator repeatability (ICC ≥0.94, CCC ≥0.94), respectively, for measurements at all 3 aspects. Least squares means (95% confidence interval) for average teat skin temperatures at the proximal, middle, and distal teat aspects, respectively, were 33.2 (32.6-33.8), 32.4 (31.5-33.2), and 30.9 (29.8-32.0) °C for operator 1, and 33.2 (32.6-33.8), 32.4 (31.6-33.3), and 31.0 (29.9-32.0) °C for operator 2. Average temperatures between duplicate scans within operators at the proximal, middle, and distal aspects, respectively, were 33.3 (32.7-33.9), 32.5 (31.7-33.3), and 31.0 (29.9-32.1) °C for the first scan and 33.2 (32.6-33.8), 32.3 (31.5-33.1), and 30.8 (29.7-31.9) °C for the second scan. We conclude that infrared thermography facilitates precise measurements of skin temperatures of cows' hind teats.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

