Prospective, Single-arm, Split-face Pain Management Evaluation of Nitrous Oxide System During Micro-Focused
Background:
Although micro-focused ultrasound with visualization (MFU-V) has great cosmetic results, patients can be hesitant or decline the treatment due to the pain experienced during the treatment. The primary objective is to assess the efficacy of pain management of the nitrous oxide system during MFU-V treatment. The secondary objectives include patient satisfaction and efficacy on reducing facial laxity and improving aesthetic appearance.
Patients And Methods:
A prospective, single-arm, split-face, open-label study. Ten patients were treated with MFU-V without use of a self-administered nitrous oxide system on the right side of the face, followed by use of the nitrous oxide system on the left. A patient-reported Visual Analog Pain Intensity Scale was used to assess pain on the right and left sides at 3 different treatment time points. Patient satisfaction was measured using a 5-point Likert scale and efficacy was measured using the Investigator GAIS and the Facial Laxity Score.
Results:
Clinically significant differences were seen between pain ratings for the treated and untreated sides at 2 of the 3 time points. 100.0% of patients (n=9) who had completed the study were very satisfied (55.6%) or somewhat satisfied (44.4%). Five patients (55.6%) were scored as Improved on the GAIS and 4 patients (44.4%) were scored as Much Improved. 90.00% (n=9) of patients had moderate lower face and neck laxity prior to treatment, compared with 11.11% (n=1) and 22.22% (n=2) with moderate laxity at follow-up.
Conclusion:
The nitrous oxide system provides clinically significant pain reduction, increases patient satisfaction, and improves cosmetic results of MFU-V treatment. J Drugs Dermatol. 2022;21(11):1228-1234. doi:10.36849/JDD.7030.
More Related Videos
06:29Real-Time Intravital Multiphoton Microscopy to Visualize Focused Ultrasound and Microbubble Treatments to Increase Blood-Brain Barrier Permeability
Published on: February 5, 2022
06:02Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
Published on: June 12, 2021
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...