99mTc-PYP SPECT and SPECT/CT quantitation for diagnosing cardiac transthyretin amyloidosis
Kenneth J Nichols1,2, Se-Young Yoon3, Andrew Van Tosh4
1Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA. knichols@northwell.edu.
Background:
We investigated quantitative 99mTc-pyrophosphate (PYP) SPECT/CT reproducibility and accuracy for diagnosing cardiac transthyretin amyloidosis (ATTR), and whether SPECT/CT improved visual and quantitative results compared to SPECT-only.
Methods:
Data were reviewed for 318 patients with suspected ATTR who underwent PYP SPECT/CT. Myocardial-to-blood pool count (MBP) ratios were computed and repeated independently > 1 month later. A physician independently scored LV myocardial-to-rib uptake on SPECT/CT as: 0 (negative), 1 < rib (equivocal), 2 = rib (positive) or 3 > rib (positive), and the image quality as: 1 (poor), 2 (adequate), and 3 (good). SPECT-only MBP ratios and visual scores were assessed separately for a subgroup of the first sequential 191 patients.
Results:
25% of patients had positive myocardial uptake (myocardial-to-rib uptake score of ≥ 2). SPECT/CT MBP ratios were reproducible (1.35 ± .68 vs 1.33 ± .74, p = .09) and corresponded with visual scores ≥ 2 (ROC AUC = 99 ± 1%) more accurately than SPECT-only MBPs (93 ± 3%, p = .02). SPECT/CT image quality was better than that of SPECT-only (2.7 ± .5 vs 2.1 ± .5, p < .0001) with fewer equivocal results (2.6% vs 22.5%, p < .0001).
Conclusion:
SPECT/CT produces MBP ratios that are reproducible and accurately identify a positive scan, with better image quality and fewer equivocal cases than SPECT-only.
More Related Videos
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...