Adoption of Improved Reprocessing Decreased Microbiological Non-Compliance for Bronchoscopes
Benedetta Tuvo1, Michela Scarpaci1, Tommaso Cosci1
1Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
Background:
In the past few decades, the inadequate reprocessing of bronchoscopes has been associated with several serious outbreaks caused by multidrug-resistant microorganisms. In this study we evaluated the improvement in the quality of reprocessing in a Bronchoscopy Unit (BU), after the introduction of a new procedure.
Methods:
In 2019, observational and clinical audits were conducted in the BU. After the introduction of an improved procedure in 2020, a microbiological surveillance plan was implemented in 2021.
Results:
In 2019, 13 of 22 bronchoscopes (59%) resulted as non-compliant, 18% as high concern organisms (HCO) and 36.4% as high microbial count (≥100 CFU/all channels) and HCO. The most frequent microorganisms were Staphylococcus aureus (38.5%) and NDM-producing Klebsiella pneumoniae (15.4%). The bronchoscopes were stored inside their transport cases, which in some cases were found to be contaminated by the same strains isolated on the bronchoscopes (Enterobacter gergoviae and Vibrio alginolyticus). In 2021, all 31 bronchoscopes were sampled at least three times and 13/99 (13.1%) resulted as non-compliant, mostly K. pneumoniae (4.04%). Contamination level increases weakly in bronchoscopes in use for more than 14 years (R = 0.32).
Conclusions:
The adoption of an improved reprocessing procedure decreased the non-compliance of bronchoscopes, increasing the quality of the process and patient safety.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...