Related Experiment Video
Updated: Aug 22, 2025

Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Diagnostics of the RC Roofing Structure of the 100-Year-Old Municipal Theatre Facility
Marta Kosior-Kazberuk1, Janusz Ryszard Krentowski1, Maciej Wardach1
1Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
Abstract:
Reinforced concrete has been a widely used material for the construction of buildings for many decades. However, with the passage of time, the material characteristics and connection of structural elements gradually degrade. Development in measurement technology makes it possible to efficiently obtain data on the current state of the structure and material characteristics using non-destructive methods, with limited or no destructive testing. The paper presents the analysis of the condition of the reinforced concrete roof of a 100-year-old theatre building in terms of its further use after planned modernisation. The tests carried out in situ as well as the computational analysis of structure are described. Based on the test results, the current load-bearing capacity was assessed and the limit state conditions were checked. Limitations on the accuracy of the non-destructive test results in relation to the destructive test results were formulated. Options for the strengthening reinforced concrete beams with regard to structural and technological considerations were analysed.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Related Concept Videos
Masonry Curtain Walls
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Reinforced Brick Masonry
To fortify brick walls...
Composite Masonry Walls
Masonry Cavity Walls
Maintaining a clean cavity during construction...
Masonry Loadbearing Walls