Related Experiment Video
Updated: Aug 22, 2025

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
Influence of the Size of Damage to the Steel Wire Rope on the Magnetic Signature
Paweł Mazurek1, Maciej Roskosz1, Jerzy Kwaśniewski1
1Department of Machinery Engineering and Transport, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, 30-059 Krakow, Poland.
Abstract:
This article presents diagnostic tests of wire ropes using passive magnetic methods. The study used two types of wire ropes with different constructions and diameters. Defects of various depths were modeled in the ropes, which reflected the degree of loss of metallic cross-section. After a series of measurements, a correlation was observed between the amplitude of the module signal and the degree of damage to the rope. The signals were recorded with the advantage of the SpinMeter-3D magnetometer. The obtained results were subjected to the extraction of features, the analysis of which allowed the damage to be identified.
More Related Videos
Related Concept Videos
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Magnetic Force On Current-Carrying Wires: Example
Magnetic Field Due to Two Straight Wires
Plastic Deformation in Circular Shafts
Magnetic Field Due To A Thin Straight Wire
Cable Subjected to a Distributed Load