Using 22C3 Anti-PD-L1 Antibody Concentrate on Biopsy and Cytology Samples from Non-small Cell Lung Cancer Patients
Published on: September 25, 2018
Nationwide differences in cytology fixation and processing methods and their impact on interlaboratory variation in
Bregje M Koomen1, Mirthe de Boer2, Carmen van Dooijeweert2
1Department of Pathology, University Medical Center Utrecht, Utrecht University, Heidelberglaan 100, Utrecht, 3584 CX, The Netherlands. b.m.koomen@umcutrecht.nl.
Abstract:
Programmed death ligand-1 (PD-L1) immunostaining, which aids clinicians in decision-making on immunotherapy for non-small cell lung cancer (NSCLC) patients, is sometimes performed on cytological specimens. In this study, differences in cytology fixation and cell block (CB) processing between pathology laboratories were assessed, and the influence of these differences on interlaboratory variation in PD-L1 positivity was investigated. Questionnaires on cytology processing were sent to all Dutch laboratories. Information gathered from the responses was added to data on all Dutch NSCLC patients with a mention of PD-L1 testing in their cytopathology report from July 2017 to December 2018, retrieved from PALGA (the nationwide network and registry of histo- and cytopathology in the Netherlands). Case mix-adjusted PD-L1 positivity rates were determined for laboratories with known fixation and CB method. The influence of differences in cytology processing on interlaboratory variation in PD-L1 positivity was assessed by comparing positivity rates adjusted for differences in the variables fixative and CB method with positivity rates not adjusted for differences in these variables. Twenty-eight laboratories responded to the survey and reported 19 different combinations of fixation and CB method. Interlaboratory variation in PD-L1 positivity was assessed in 19 laboratories. Correcting for differences in the fixative and CB method resulted in a reduction (from eight (42.1%) to five (26.3%)) in the number of laboratories that differed significantly from the mean in PD-L1 positivity. Substantial variation in cytology fixation and CB processing methods was observed between Dutch pathology laboratories, which partially explains the existing considerable interlaboratory variation in PD-L1 positivity.
More Related Videos
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019
09:32Multiplexed Immunofluorescence Analysis and Quantification of Intratumoral PD-1+ Tim-3+ CD8+ T Cells
Published on: February 8, 2018